TRAINING FAAA_004 MATERIAL, FREE SAMPLE FAAA_004 QUESTIONS

Training FAAA_004 Material, Free Sample FAAA_004 Questions

Training FAAA_004 Material, Free Sample FAAA_004 Questions

Blog Article

Tags: Training FAAA_004 Material, Free Sample FAAA_004 Questions, Valid FAAA_004 Exam Camp, FAAA_004 Study Materials Review, Latest FAAA_004 Exam Camp

There are numerious FAAA_004 exam dumps for the candidates to select for their preparation the exams, some candidates may get confused by so many choice. Our FAAA_004 learning materials have free demo for the candidates, and they will have a general idea about the FAAA_004 Learning Materials. You can obtain the FAAA_004 learning materials for about ten minutes. The payment is also quite easy: online payment with credit card, and the private information of the you is also guaranteed.

Pure Storage FAAA_004 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Array Monitoring and Architecture: This section measures the skills of Storage Architects and covers explaining FlashArray's high availability architecture, defining FlashArray features (e.g., ActiveCluster, ActiveDR), explaining data reduction methods, identifying components of FlashArrays, and analyzing performance metrics and capacity usage using Pure1 Manage3. A crucial skill evaluated is "analyzing performance metrics".
Topic 2
  • Subscriptions and DX: This section evaluates the competencies of Account Managers regarding Pure Storage's subscription services and digital experience. It focuses on identifying the benefits of Pure's Evergreen program (Evergreen
  • One,
  • Forever,
  • Flex) and Love Your Storage Guarantee, as well as determining future capacity, performance, and upgrade requirements through workload and hardware simulations.
Topic 3
  • Qualify, Sell, and Architect: This section of the exam assesses the skills of Technical Sales Engineers and covers identifying solutions based on customer requirements, sizing solutions based on customer needs using tools like Pure FlashArray Sizer, identifying market trends and opportunities (e.g., Ransomware and Portworx Solution Centers), demonstrating an understanding of FlashArray use cases, and demonstrating an understanding of unified storage on FlashArray37. A key skill measured is "identifying solutions based on customer requirements.

>> Training FAAA_004 Material <<

Free Sample FAAA_004 Questions - Valid FAAA_004 Exam Camp

Owning the ITexamReview FAAA_004 exam certification training materials is equal to have a bright future, and equal to own the key to success. After you purchase ITexamReview's FAAA_004 certification exam training materials, we will provide one year free renewal service. If there's any quality problem in FAAA_004 Exam Dumps or you fail FAAA_004 exam certification, we will give a full refund unconditionally.

Pure Storage FlashArray Architect Associate Sample Questions (Q26-Q31):

NEW QUESTION # 26
A customer has a requirement for 450 TB of block storage to support their tier2 environment where latency is not a concern. The workload is expected to achieve a 4-to-l data reduction.
Which array and capacity configuration is the minimum required to meet their needs?

  • A. FlashArray//C60R3 366 TB
  • B. FlashArray//X70R3 228 TB
  • C. FlashArray//C40R3 247 TB
  • D. FlashArray//C60R3 878 TB

Answer: C

Explanation:
To meet the customer's requirement for 450 TB of block storage with a 4:1 data reduction ratio, we need to calculate the effective usable capacity required and select the appropriate array configuration.
Step-by-Step Calculation:
Effective Usable Capacity Needed :
The workload requires 450 TB of logical storage.
With a 4:1 data reduction ratio, the physical storage required is:

Array Selection :
The selected array must provide at least 112.5 TB of usable capacity after accounting for overhead and RAID protection.
Let's evaluate the options:
A . FlashArray//C40R3 247 TB :
The FlashArray//C40R3 provides 247 TB of raw capacity. After accounting for overhead (typically ~20%), the usable capacity is approximately:Usable Capacity=247TB×0.8=197.6TB.
This exceeds the required 112.5 TB , making it a valid option.
B . FlashArray//C60R3 878 TB :
The FlashArray//C60R3 provides 878 TB of raw capacity, which is significantly larger than needed. While it meets the requirement, it is not the minimum configuration.
C . FlashArray//X70R3 228 TB :
The FlashArray//X70R3 provides 228 TB of raw capacity. After overhead, the usable capacity is approximately:Usable Capacity=228TB×0.8=182.4TB.
While this also meets the requirement, it is more expensive than the C40R3.
D . FlashArray//C60R3 366 TB :
The FlashArray//C60R3 with 366 TB of raw capacity is overkill for this requirement and not cost-effective.
Recommendation :
The FlashArray//C40R3 247 TB provides the minimum required usable capacity while meeting the customer's needs.
Final Recommendation:
The correct answer is A. FlashArray//C40R3 247 TB .
Reference:
FlashArray//C Series Product Overview :
FlashArray//C Series
Details the capacity and use cases for FlashArray//C models.
Capacity Planning Guide :
Pure Storage Capacity Planning
Provides guidance on calculating usable capacity based on data reduction ratios.


NEW QUESTION # 27
What causes a disruption to Pure FlashArray stateless controller operations or performance, if there is a single array?

  • A. Replacing a controller 10 module
  • B. Upgrade Purity//FA code
  • C. Moving from a SAS- to NVMe-based shelf
  • D. Physically relocating an array

Answer: D

Explanation:
Among the listed options, physically relocating an array is the action most likely to cause a disruption to Pure FlashArray stateless controller operations or performance.
Why This Matters:
Physical Relocation:
Moving a FlashArray involves powering down the system, disconnecting cables, and transporting the hardware to a new location. This process inherently disrupts operations and performance until the array is reinstalled and brought back online.
Even with proper planning, physical relocation introduces downtime and potential risks (e.g., hardware damage during transport).
Why Not the Other Options?
A . Replacing a controller I/O module:
FlashArray controllers are designed with redundancy and hot-swappable components. Replacing an I/O module typically does not cause significant disruptions, as the other controller continues to handle operations.
C . Moving from a SAS- to NVMe-based shelf:
Transitioning to NVMe-based shelves is a planned upgrade that does not inherently disrupt operations. The array can continue functioning during the transition, though performance may vary temporarily.
D . Upgrade Purity//FA code:
Upgrading Purity//FA (the operating system for FlashArray) is a non-disruptive process. FlashArray supports rolling upgrades, ensuring continuous availability and performance during the update.
Key Points:
Physical Relocation: Causes unavoidable downtime and operational disruption.
Redundancy and Non-Disruptive Operations: FlashArray is designed to minimize disruptions for tasks like module replacement and software upgrades.
Planning Required: Physical relocation requires careful planning to minimize risks and downtime.
Reference:
Pure Storage FlashArray Documentation: "Maintenance and Relocation Best Practices" Pure Storage Whitepaper: "Non-Disruptive Operations with FlashArray" Pure Storage Knowledge Base: "Minimizing Disruptions During Array Maintenance"


NEW QUESTION # 28
A potential customer has a use case where they need to use a stretched cluster for high availability and also require a third copy of their data in a remote geographic location.
Which replication method should be recommended?

  • A. Fan-out asynchronous snapshot replication
  • B. ActiveDR with periodic snapshot replication
  • C. CloudSnap to an offload target
  • D. ActiveCluster with asychronous snapshot replication

Answer: D

Explanation:
The customer requires a storage solution that supports a stretched cluster for high availability and also maintains a third copy of their data in a remote geographic location . The best replication method to recommend is ActiveCluster with asynchronous snapshot replication .
Why This Matters:
ActiveCluster:
ActiveCluster provides synchronous replication between two sites within a stretched cluster, ensuring zero RPO and near-zero RTO for high availability.
It is ideal for scenarios where applications require continuous access to data across two locations.
Asynchronous Snapshot Replication:
Asynchronous replication extends the disaster recovery strategy by replicating snapshots to a third site. This ensures an additional layer of protection against regional failures.
Why Not the Other Options?
A . CloudSnap to an offload target:
CloudSnap is used to offload snapshots to cloud storage (e.g., AWS S3 or Azure Blob). While it satisfies the requirement for a third copy, it does not integrate with ActiveCluster for high availability in a stretched cluster.
B . Fan-out asynchronous snapshot replication:
Fan-out replication involves sending snapshots to multiple targets asynchronously. However, it does not provide the synchronous replication required for a stretched cluster.
C . ActiveDR with periodic snapshot replication:
ActiveDR is designed for asynchronous replication and failover/failback scenarios but does not support synchronous replication for a stretched cluster.
Key Points:
ActiveCluster: Ensures high availability with synchronous replication in a stretched cluster.
Async Replication: Adds a third-site replication target for comprehensive disaster recovery.
Integrated Solution: Combines high availability and disaster recovery into a single architecture.
Reference:
Pure Storage FlashArray Documentation: "ActiveCluster with Async Replication" Pure Storage Whitepaper: "Disaster Recovery Strategies with FlashArray" Pure Storage Knowledge Base: "Using Protection Groups in Stretched Pods"


NEW QUESTION # 29
Which two features are specific to the Evergreen//Forever Program and are NOT included with Evergreen//Foundation? (Choose two.)

  • A. Controller Upgrades
  • B. Pro Deployment
  • C. Upgrade Always
  • D. Capacity Consolidation

Answer: A,C

Explanation:
The Evergreen//Forever program is Pure Storage's premium subscription offering, providing continuous upgrades and enhancements to ensure customers always have access to the latest technology. In contrast, Evergreen//Foundation is a lower-tier subscription with limited benefits. Here's an analysis of the features:
Correct Features:
A . Controller Upgrades :
Controller upgrades are a key feature of Evergreen//Forever, allowing customers to upgrade their FlashArray controllers non-disruptively to newer generations.
This feature is not included in Evergreen//Foundation.
D . Upgrade Always :
"Upgrade Always" ensures that customers can continuously upgrade their hardware and software without additional costs.
This is a hallmark of Evergreen//Forever and is not available in Evergreen//Foundation.
Incorrect Features:
B . Pro Deployment :
Pro Deployment services are available across all Evergreen tiers, including Evergreen//Foundation.
Therefore, this is not specific to Evergreen//Forever.
C . Capacity Consolidation :
Capacity consolidation is a general benefit of Pure Storage arrays and is not exclusive to Evergreen//Forever.
It is also available in Evergreen//Foundation.
Final Recommendation:
The correct answers are A. Controller Upgrades and D. Upgrade Always , as these are specific to Evergreen//Forever and not included in Evergreen//Foundation.
Reference:
Evergreen//Forever Program Overview :
Evergreen//Forever
Explains the benefits and features of Evergreen//Forever.
Evergreen Subscription Tiers Comparison :
Evergreen Tiers
Compares the features of Evergreen//Forever and Evergreen//Foundation.


NEW QUESTION # 30
A controller receives a write request.
If it generates a hash that is already recorded in the hash table, what happens next?

  • A. The next incoming block is then hashed to see if it can be deduplicated.
  • B. Deep level compression is then applied to the newly hashed block.
  • C. Purity//FA will expand the block to see if it can deduplicate a larger dataset.
  • D. The new block is compared to the existing block to confirm they are duplicates.

Answer: D

Explanation:
When a controller generates a hash for an incoming write request and finds that the hash already exists in the hash table, the next step is to compare the new block to the existing block to confirm they are duplicates .
Why This Matters:
Hash Collision Handling:
Hash functions can sometimes produce the same hash value for different data blocks (a "hash collision"). To ensure data integrity, the system must verify that the new block is identical to the existing block before deduplication occurs.
Data Integrity:
Comparing the blocks ensures that only true duplicates are deduplicated, preventing data corruption or loss due to hash collisions.
Why Not the Other Options?
A . The next incoming block is then hashed to see if it can be deduplicated:
Hashing the next block is unnecessary at this stage. The focus is on verifying whether the current block is a duplicate.
B . Deep level compression is then applied to the newly hashed block:
Compression is a separate process from deduplication and does not occur immediately after hashing.
D . Purity//FA will expand the block to see if it can deduplicate a larger dataset:
Expanding the block is not part of the deduplication process. Deduplication operates on individual blocks, not larger datasets.
Key Points:
Hash Table Lookup: Identifies potential duplicates based on hash values.
Block Comparison: Confirms that the new block matches the existing block to ensure data integrity.
Deduplication: Eliminates redundant data to optimize storage efficiency.
Reference:
Pure Storage FlashArray Documentation: "Understanding Deduplication in Purity//FA" Pure Storage Whitepaper: "Data Reduction Techniques in FlashArray" Pure Storage Knowledge Base: "How Deduplication Works in FlashArray"


NEW QUESTION # 31
......

Our FAAA_004 training materials are compiled by professional experts. All the necessary points have been mentioned in our FAAA_004 practice engine particularly. About some tough questions or important points, they left notes under them. Besides, our experts will concern about changes happened in FAAA_004 study prep all the time. Provided you have a strong determination, as well as the help of our FAAA_004 learning guide, you can have success absolutely.

Free Sample FAAA_004 Questions: https://www.itexamreview.com/FAAA_004-exam-dumps.html

Report this page